Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Nick from JOPLIN, MO
Parts Used:
5304476057
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Bearings in fan motor were bad causing a loud grinding sound.
Pull the front and outside shell off and the got the Styrofoam off and all necessary screws. Undid the wires and reran everything.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randy from Sumas, WA
Parts Used:
5304476059
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Fan Blade Broken
I took all of the outer screws out and removed sheet metal cover. I had to unbolt fan motor from bottom of the unit. I moved the fan motor so I could remove the Fan Blade. Put new blade on and reversed the process. Works Fine.
Was this instruction helpful to you?
Thank you for voting!